Microwave Technique Based Noninvasive Monitoring of Intracranial Pressure Using Realistic Phantom Models
Singh, Daljeet; Vihriälä, Erkki; Särestöniemi, Mariella; Myllylä, Teemu (2024-05-05)
Singh, Daljeet
Vihriälä, Erkki
Särestöniemi, Mariella
Myllylä, Teemu
Springer
05.05.2024
Singh, D., Vihriälä, E., Särestöniemi, M., Myllylä, T. (2024). Microwave Technique Based Noninvasive Monitoring of Intracranial Pressure Using Realistic Phantom Models. In: Särestöniemi, M., et al. Digital Health and Wireless Solutions. NCDHWS 2024. Communications in Computer and Information Science, vol 2084. Springer, Cham. https://doi.org/10.1007/978-3-031-59091-7_27
https://creativecommons.org/licenses/by/4.0/
© 2024 The Author(s). This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made. The images or other third party material in this chapter are included in the chapter’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
https://creativecommons.org/licenses/by/4.0/
© 2024 The Author(s). This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made. The images or other third party material in this chapter are included in the chapter’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
https://creativecommons.org/licenses/by/4.0/
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:oulu-202405304099
https://urn.fi/URN:NBN:fi:oulu-202405304099
Tiivistelmä
Abstract
Microwave technology is emerging as a promising candidate in the field of medical diagnosis and imaging and has paved the way for a transition from invasive to non-invasive methods of monitoring various biological phenomena inside the human body. Intracranial Pressure (ICP) is considered to be a very important parameter by medical practitioners for assessing the health of a subject. Accurate, prolonged, and noninvasive measurement of ICP is still an open area of research with no clinical success so far. Therefore, in this paper, a microwave-based method for non-invasive monitoring of ICP is proposed. The setup utilizes flexible, thin, small, and lightweight planner antennas that are very suitable for non-invasive monitoring of ICP from the skin without compromising the comfort of subject. The proposed microwave method is tested on a realistic head phantom model which imitates the functioning of hydrodynamics in a real human head. The measurement results from the proposed method are verified using invasive pressure sensors. It is deduced from numerous trials that the proposed microwave system can detect small changes in ICP pressure and its response is analogous to actual pressure values measured by invasive pressure sensors.
Microwave technology is emerging as a promising candidate in the field of medical diagnosis and imaging and has paved the way for a transition from invasive to non-invasive methods of monitoring various biological phenomena inside the human body. Intracranial Pressure (ICP) is considered to be a very important parameter by medical practitioners for assessing the health of a subject. Accurate, prolonged, and noninvasive measurement of ICP is still an open area of research with no clinical success so far. Therefore, in this paper, a microwave-based method for non-invasive monitoring of ICP is proposed. The setup utilizes flexible, thin, small, and lightweight planner antennas that are very suitable for non-invasive monitoring of ICP from the skin without compromising the comfort of subject. The proposed microwave method is tested on a realistic head phantom model which imitates the functioning of hydrodynamics in a real human head. The measurement results from the proposed method are verified using invasive pressure sensors. It is deduced from numerous trials that the proposed microwave system can detect small changes in ICP pressure and its response is analogous to actual pressure values measured by invasive pressure sensors.
Kokoelmat