Influence of Arterial Vessel Diameter and Blood Viscosity on PTT in Pulsatile Flow Model
Zienkiewicz, Aleksandra; Vihriälä, Erkki; Myllylä, Teemu (2024-05-05)
Zienkiewicz, Aleksandra
Vihriälä, Erkki
Myllylä, Teemu
Springer
05.05.2024
Zienkiewicz, A., Vihriälä, E., Myllylä, T. (2024). Influence of Arterial Vessel Diameter and Blood Viscosity on PTT in Pulsatile Flow Model. In: Särestöniemi, M., et al. Digital Health and Wireless Solutions. NCDHWS 2024. Communications in Computer and Information Science, vol 2084. Springer, Cham. https://doi.org/10.1007/978-3-031-59091-7_13
https://creativecommons.org/licenses/by/4.0/
© 2024 The Author(s). This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made. The images or other third party material in this chapter are included in the chapter’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
https://creativecommons.org/licenses/by/4.0/
© 2024 The Author(s). This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made. The images or other third party material in this chapter are included in the chapter’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
https://creativecommons.org/licenses/by/4.0/
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi:oulu-202405304093
https://urn.fi/URN:NBN:fi:oulu-202405304093
Tiivistelmä
Abstract
Modelling relation between Pulse Transit Time (PTT) and blood pressure (BP) is a critical step in BP estimation for wearable technology. Recognizing the limitation of assuming constant vessel and blood conditions, we developed a simplified pulsatile flow model to analyze how various factors affect PTT values. Our research focuses on the impact of mechanical characteristics, such as vessel diameter, wall thickness, blood viscosity, and pressure, on PTT measurements and subsequent BP estimation. Measurements were conducted using accelerometer sensors within a custom-designed mock circulatory loop. This setup allowed for the testing of a wide range of pressure values and pulsation rates, as well as the modification of viscosity in blood-mimicking liquids across different vessel models. We employed the Moens-Korteweg conversion model for pressure estimation, initially trained on PTT data from a specific setup parameter combination, and subsequently tested with data from varied setup parameters. We observed high correlation levels (r = 0.93 ± 0.09) paired with high error (RMSE = 163 ± 100 mHg), suggesting potential inaccuracies in pressure estimation. We present the recorded signals and discuss how alterations in physical conditions influence PTT values and the precision of BP estimation.
Modelling relation between Pulse Transit Time (PTT) and blood pressure (BP) is a critical step in BP estimation for wearable technology. Recognizing the limitation of assuming constant vessel and blood conditions, we developed a simplified pulsatile flow model to analyze how various factors affect PTT values. Our research focuses on the impact of mechanical characteristics, such as vessel diameter, wall thickness, blood viscosity, and pressure, on PTT measurements and subsequent BP estimation. Measurements were conducted using accelerometer sensors within a custom-designed mock circulatory loop. This setup allowed for the testing of a wide range of pressure values and pulsation rates, as well as the modification of viscosity in blood-mimicking liquids across different vessel models. We employed the Moens-Korteweg conversion model for pressure estimation, initially trained on PTT data from a specific setup parameter combination, and subsequently tested with data from varied setup parameters. We observed high correlation levels (r = 0.93 ± 0.09) paired with high error (RMSE = 163 ± 100 mHg), suggesting potential inaccuracies in pressure estimation. We present the recorded signals and discuss how alterations in physical conditions influence PTT values and the precision of BP estimation.