Hyppää sisältöön
    • FI
    • ENG
  • FI
  • /
  • EN
OuluREPO – Oulun yliopiston julkaisuarkisto / University of Oulu repository
Näytä viite 
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Experimental wireless link and SAR assessments of an implantable PIFA for biotelemetry in the 2.45 GHz band

Zulkefli, Muhammad Solihin; Zhang, Kai; Särestöniemi, Mariella; Myllymäki, Sami; Whittow, William G.; Yan, Sen; Soh, Ping Jack (2023-07-28)

 
Avaa tiedosto
nbnfi-fe20230822100764.pdf (2.102Mt)
nbnfi-fe20230822100764_meta.xml (43.58Kt)
nbnfi-fe20230822100764_solr.xml (36.33Kt)
Lataukset: 

URL:
https://doi.org/10.1109/JERM.2023.3294707

Zulkefli, Muhammad Solihin
Zhang, Kai
Särestöniemi, Mariella
Myllymäki, Sami
Whittow, William G.
Yan, Sen
Soh, Ping Jack
Institute of Electrical and Electronics Engineers
28.07.2023

M. S. Zulkefli et al., "Experimental Wireless Link and SAR Assessments of an Implantable PIFA for Biotelemetry in the 2.45 GHz Band," in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, vol. 7, no. 3, pp. 281-289, Sept. 2023, doi: 10.1109/JERM.2023.3294707.

https://rightsstatements.org/vocab/InC/1.0/
© 2023 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See https://www.ieee.org/publications/rights/index.html for more information.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1109/JERM.2023.3294707
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe20230822100764
Tiivistelmä

Abstract

An experimental wireless link and specific absorption rate (SAR) assessment is presented in this work. A compact planar inverted-F antenna (PIFA) is designed and evaluated for biotelemetry application as an antenna at 2.45 GHz band. The proposed antenna provided a satisfactory bandwidth per unit volume using a two-layered stacked structure consisting of a high-frequency laminate and a low loss ceramic layer. The antenna was first co-designed inside several different types of phantom boxes to optimize its performance, considering computational resources. Next, a semisolid intestinal phantom model used in simulations were chosen to be fabricated for experimental evaluations. Evaluation results indicated a satisfactory antenna’s operation from 2.13 to 2.81 GHz (bandwidth of 27.8%), with realized gains of −26.49 dBi when implanted at 45 mm inside the phantom. Next, measurements were performed on the antenna’s communication link with a wearable antenna to study the effects its depth (from 10 to 45mm), indicating transmission coefficients of between −40 and −60 dB at 2.45 GHz. Finally, its SAR levels are evaluated experimentally using a commercial measurement system when implanted within the human tissue. Results indicated satisfactory level of 0.685 W/kg (averaged over 10 g of tissues) and is suitable for biotelemetry application.

Kokoelmat
  • Avoin saatavuus [37744]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen