Heat exchanger fouling estimation for combustion–thermal power plants including load level dynamics

Neuvonen, Markus; Selek, István; Ikonen, Enso; Aho, Lauri (2022-11-18)

 
Avaa tiedosto
nbnfi-fe202301317784.pdf (487.2Kt)
nbnfi-fe202301317784_meta.xml (36.18Kt)
nbnfi-fe202301317784_solr.xml (30.05Kt)
Lataukset: 

URL:
https://doi.org/10.1109/SMC53654.2022.9945541

Neuvonen, Markus
Selek, István
Ikonen, Enso
Aho, Lauri
Institute of Electrical and Electronics Engineers
18.11.2022

M. Neuvonen, I. Selek, E. Ikonen and L. Aho, "Heat exchanger fouling estimation for combustion–thermal power plants including load level dynamics," 2022 IEEE International Conference on Systems, Man, and Cybernetics (SMC), Prague, Czech Republic, 2022, pp. 2987-2992, doi: 10.1109/SMC53654.2022.9945541.

https://rightsstatements.org/vocab/InC/1.0/
© 2022 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1109/SMC53654.2022.9945541
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe202301317784
Tiivistelmä

Abstract

This paper presents a robust soft sensor for estimating heat exchanger fouling in combustion–thermal power plant context. The approach is data–driven and focuses on identifying the effect of plant load changes to fouling estimation. Proposed method is applied to real process measurements and results are presented. The method consists of two blocks; a static energy balance calculation block for “traditional” fouling indicator calculation and a dynamic subspace identification block for finding sootblowing– and load level dynamics components of the static fouling indicator signal. Results from applying the proposed method to real plant data show that load level dynamics can be decoupled from static fouling estimate.

Kokoelmat
  • Avoin saatavuus [38841]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja