Repeatability of 220 - 330 GHz variable waveguide attenuator and frequency extenders for 6G measurements

Leinonen, Marko E.; Mäkelä, Juha-Pekka; Nevala, Klaus; Tervo, Nuutti; Pärssinen, Aarno (2022-08-01)

 
Avaa tiedosto
nbnfi-fe2022092159714.pdf (2.245Mt)
nbnfi-fe2022092159714_meta.xml (39.80Kt)
nbnfi-fe2022092159714_solr.xml (29.30Kt)
Lataukset: 

URL:
https://doi.org/10.1109/arftg52954.2022.9844108

Leinonen, Marko E.
Mäkelä, Juha-Pekka
Nevala, Klaus
Tervo, Nuutti
Pärssinen, Aarno
Institute of Electrical and Electronics Engineers
01.08.2022

M. E. Leinonen, J. -P. Mäkelä, K. Nevala, N. Tervo and A. Pärssinen, "Repeatability of 220–330 GHz Variable Waveguide Attenuator and Frequency Extenders for 6G Measurements," 2022 98th ARFTG Microwave Measurement Conference (ARFTG), 2022, pp. 1-4, doi: 10.1109/ARFTG52954.2022.9844108.

https://rightsstatements.org/vocab/InC/1.0/
© 2022 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1109/arftg52954.2022.9844108
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2022092159714
Tiivistelmä

Abstract

Mechanical waveguide attenuators are used above 100 GHz frequencies to control signal levels in power sweep measurements to avoid compression of the device or the extender. However, manual settings of the attenuators are prone to human errors, and thus the repeatability of each measurement need be studied case-basis. This paper studies calibration accuracy of extenders, and the repeatability and reproducibility of a waveguide attenuator operating at 220 to 330 GHz. The average calibration variation of S 21 with three operators and three repeated calibrations over frequencies was -0.009 dB and 0.072° for directly connected frequency extenders. The measured setting accuracy of any waveguide setting was 1.4 dB (±2σ) over 15 dB range. The primary source of measured variation in S 11 and S 21 in variable attenuator setting measurements was due to repetition of measurements since there was no significant statistical difference between three operators.

Kokoelmat
  • Avoin saatavuus [38865]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen