Imitation of optical coherence tomography images by wave Monte Carlo-based approach implemented with the Leontovich-Fock equation

Bulygin, Andrey D.; Vrazhnov, Denis A.; Sim, Elena S.; Meglinski, Igor; Kistenev, Yury V. (2020-02-28)

 
Avaa tiedosto
nbnfi-fe202102195394.pdf (2.000Mt)
nbnfi-fe202102195394_meta.xml (36.02Kt)
nbnfi-fe202102195394_solr.xml (36.71Kt)
Lataukset: 

URL:
https://doi.org/10.1117/1.OE.59.6.061626

Bulygin, Andrey D.
Vrazhnov, Denis A.
Sim, Elena S.
Meglinski, Igor
Kistenev, Yury V.
SPIE
28.02.2020

Andrey D. Bulygin, Denis A. Vrazhnov, Elena S. Sim, Igor Meglinski, and Yury V. Kistenev "Imitation of optical coherence tomography images by wave Monte Carlo-based approach implemented with the Leontovich–Fock equation," Optical Engineering 59(6), 061626 (28 February 2020). https://doi.org/10.1117/1.OE.59.6.061626

https://rightsstatements.org/vocab/InC/1.0/
© 2020 Society of Photo-Optical Instrumentation Engineers (SPIE) 0091-3286/2020/$28.00 © 2020 SPIE.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1117/1.OE.59.6.061626
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe202102195394
Tiivistelmä

Abstract

We present a computational modeling approach for imitation of the time-domain optical coherence tomography (OCT) images of biotissues. The developed modeling technique is based on the implementation of the Leontovich–Fock equation into the wave Monte Carlo (MC) method. We discuss the benefits of the developed computational model in comparison to the conventional MC method based on the modeling of OCT images of a nevus. The developed model takes into account diffraction on bulk-absorbing microstructures and allows consideration of the influence of the amplitude–phase profile of the wave beam on the quality of the OCT images. The selection of optical parameters of modeling medium, used for simulation of optical radiation propagation in biotissues, is based on the results obtained experimentally by OCT. The developed computational model can be used for imitation of the light waves propagation both in time-domain and spectral-domain OCT approaches.

Kokoelmat
  • Avoin saatavuus [38841]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja