Eucapnic voluntary hyperventilation test decreases exhaled nitric oxide level in children

Burman, Janne; Malmberg, Pekka; Elenius, Varpu; Lukkarinen, Heikki; Kuusela, Tom; Mäkelä, Mika; Remes, Sami; Jartti, Tuomas (2020-10-27)

 
Avaa tiedosto
nbnfi-fe202102043706.pdf (4.236Mt)
nbnfi-fe202102043706_meta.xml (44.45Kt)
nbnfi-fe202102043706_solr.xml (43.75Kt)
Lataukset: 

URL:
https://doi.org/10.1111/cpf.12673

Burman, Janne
Malmberg, Pekka
Elenius, Varpu
Lukkarinen, Heikki
Kuusela, Tom
Mäkelä, Mika
Remes, Sami
Jartti, Tuomas
John Wiley & Sons
27.10.2020

Burman, J, Malmberg, P, Elenius, V, et al. Eucapnic voluntary hyperventilation test decreases exhaled nitric oxide level in children. Clin Physiol Funct Imaging. 2020; 41: 1– 3. https://doi.org/10.1111/cpf.12673

https://rightsstatements.org/vocab/InC/1.0/
© 2020 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd. This is the peer reviewed version of the following article: Burman, J, Malmberg, P, Elenius, V, et al. Eucapnic voluntary hyperventilation test decreases exhaled nitric oxide level in children. Clin Physiol Funct Imaging. 2020; 41: 1– 3, which has been published in final form at https://doi.org/10.1111/cpf.12673. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving."
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1111/cpf.12673
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe202102043706
Tiivistelmä

Abstract

Background: Exhaled nitric oxide (FeNO) measurements and eucapnic voluntary hyperventilation (EVH) tests have been used as diagnostic tools for asthma. Data on the impact of hyperventilation on the level of FeNO are limited.

Aim: We aimed to evaluate whether EVH tests affect the level of FeNO in children aged 10–16 years.

Methods: A total of 234 children aged 10–16 years had a 6‐min EVH test performed. In total, FeNO values for 153 of 234 children were measured before the test and within 15 min after the test. According to a baseline FeNO level of 20 ppb, children were divided into two groups: those with low values (FeNO < 20 ppb) and those with high values (FeNO ≥ 20 ppb).

Results: The median age of the children was 13.4 years (interquartile range 12.3–15.3 years); 58% were boys and 42% were girls. Of these children, 51% were sensitized to aeroallergens. In 101 of 153 children (66%), the FeNO values decreased after the EVH test. In children with low and high baseline levels, the median level of FeNO decreased after the EVH test: 10.5 ppb before versus 9.5 ppb after (p < .011), and 31.0 ppb before versus 28.0 ppb after (p < .011), respectively. The decrease in FeNO after EVH test was not associated with induced bronchoconstriction expressed as a change in FEV1 (Rs = .19).

Conclusions: The EVH test decreases FeNO levels. Therefore, FeNO should be measured before an EVH test is performed.

Kokoelmat
  • Avoin saatavuus [37744]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen