Hyppää sisältöön
    • FI
    • ENG
  • FI
  • /
  • EN
OuluREPO – Oulun yliopiston julkaisuarkisto / University of Oulu repository
Näytä viite 
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Analysis of hygrothermal performance of low-energy house in Nordic climate

Fedorik, Filip; Alitalo, Sanna; Savolainen, Jukka-Pekka; Räinä, Ilkka; Illikainen, Kimmo (2021-01-11)

 
Avaa tiedosto
nbnfi-fe2021121460362.pdf (2.033Mt)
nbnfi-fe2021121460362_meta.xml (35.58Kt)
nbnfi-fe2021121460362_solr.xml (29.46Kt)
Lataukset: 

URL:
https://doi.org/10.1177/1744259120984187

Fedorik, Filip
Alitalo, Sanna
Savolainen, Jukka-Pekka
Räinä, Ilkka
Illikainen, Kimmo
SAGE Publications
11.01.2021

Fedorik, F., Alitalo, S., Savolainen, J.-P., Räinä, I., & Illikainen, K. (2021). Analysis of hygrothermal performance of low-energy house in Nordic climate. Journal of Building Physics, 45(3), 344–367. https://doi.org/10.1177/1744259120984187

https://rightsstatements.org/vocab/InC/1.0/
© 2021 SAGE Publications. The final authenticated version is available online at https://doi.org/10.1177/1744259120984187.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1177/1744259120984187
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2021121460362
Tiivistelmä

Abstract

Analyses of hygrothermal conditions in low-energy houses is important because of their likely sensitivity for excessive moisture. The presented work deals with real-time measurement of temperature and relative humidity at multiple locations inside a low-energy house envelope. The measured data allows diagnosing approaches towards building design and understanding and evaluating the house performance. Suitability and accuracy of numerical computation was analysed. The Finnish mould growth model was used to monitor risk and extent of mould growth under measured and computed conditions. The measured conditions represent more favourable environment to avoid mould growth than the design values recommended by national and international guidelines. There was no mould growth indicated at any monitored points of the envelope. Monitoring the hygrothermal conditions provides valuable information about the performance of structural elements, building material and the house envelope and it helps to predict moisture related risks during the building’s service life.

Kokoelmat
  • Avoin saatavuus [38618]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen