Hyppää sisältöön
    • FI
    • ENG
  • FI
  • /
  • EN
OuluREPO – Oulun yliopiston julkaisuarkisto / University of Oulu repository
Näytä viite 
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

An integrated 9x9 SPAD array with a 10-channel TDC and a CMOS laser diode driver for a wearable time-domain diffuse optics optode

Jansson, Jussi-Pekka; Jahromi, Sahba; Haapalainen, Kalle; Juttula, Harri; Mäkynen, Anssi; Nissinen, Jan (2020-06-30)

 
Avaa tiedosto
nbnfi-fe2020100577994.pdf (1.013Mt)
nbnfi-fe2020100577994_meta.xml (42.57Kt)
nbnfi-fe2020100577994_solr.xml (34.63Kt)
Lataukset: 

URL:
https://doi.org/10.1109/I2MTC43012.2020.9129341

Jansson, Jussi-Pekka
Jahromi, Sahba
Haapalainen, Kalle
Juttula, Harri
Mäkynen, Anssi
Nissinen, Jan
Institute of Electrical and Electronics Engineers
30.06.2020

J. Jansson, S. Jahromi, K. Haapalainen, H. Juttula, A. Mäkynen and J. Nissinen, "An integrated 9x9 SPAD array with a 10-channel TDC and a CMOS laser diode driver for a wearable time-domain diffuse optics optode," 2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Dubrovnik, Croatia, 2020, pp. 1-5, doi: 10.1109/I2MTC43012.2020.9129341

https://rightsstatements.org/vocab/InC/1.0/
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1109/I2MTC43012.2020.9129341
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2020100577994
Tiivistelmä

Abstract

A 9x9 Single-Photon Avalanche Photodiode (SPAD) array with a 10-channel time-to-digital converter and an integrated laser diode driver fabricated in 0.35 μm HV- CMOS technology were used to carry out time domain diffuse optics measurements of optical phantoms. The average optical power of 20 μW was achieved by the laser diode transmitter at the repetition rate of 500 kHz with a pulse width of 80 ps. The resolution of the TDC and the measured instrument response function (IRF) of the system were ~65 ps and ~190 ps, respectively. The power consumption of the proposed system was 180 mW. Measurements showed that with the proposed system a perturbation with a different absorption property than in surrounding material at the depth of 15 mm could be recognized. In addition, in in vivo measurement with the proposed components, hemodynamic changes in volunteer’s arm during a venous occlusion were detected.

Kokoelmat
  • Avoin saatavuus [38841]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen