Improving signal detection in emission optical projection tomography via single source multi-exposure image fusion

Cheddad, Abbas; Nord, Christoffer; Hörnblad, Andreas; Prunskaite-Hyyryläinen, Renata; Eriksson, Maria; Georgsson, Fredrik; Vainio, Seppo J.; Ahlgren, Ulf (2013-05-01)

 
Avaa tiedosto
nbnfi-fe2020050825844.pdf (27.28Mt)
nbnfi-fe2020050825844_meta.xml (47.27Kt)
nbnfi-fe2020050825844_solr.xml (30.76Kt)
Lataukset: 

URL:
https://doi.org/10.1364/OE.21.016584

Cheddad, Abbas
Nord, Christoffer
Hörnblad, Andreas
Prunskaite-Hyyryläinen, Renata
Eriksson, Maria
Georgsson, Fredrik
Vainio, Seppo J.
Ahlgren, Ulf
Optical Society of America
01.05.2013

Cheddad, A., Nord, C., Hörnblad, A., Prunskaite-Hyyryläinen, R., Eriksson, M., Georgsson, F., Vainio, S., Ahlgren, U. (2013) Improving signal detection in emission optical projection tomography via single source multi-exposure image fusion. Optics Express, 21 (14), 16584-16604. https://doi.org/10.1364/OE.21.016584

https://rightsstatements.org/vocab/InC/1.0/
©2013 Optical Society of America.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1364/OE.21.016584
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2020050825844
Tiivistelmä

Abstract

We demonstrate a technique to improve structural data obtained from Optical Projection Tomography (OPT) using Image Fusion (IF) and contrast normalization. This enables the visualization of molecular expression patterns in biological specimens with highly variable contrast values. In the approach, termed IF-OPT, different exposures are fused by assigning weighted contrasts to each. When applied to projection images from mouse organs and digital phantoms our results demonstrate the capability of IF-OPT to reveal high and low signal intensity details in challenging specimens. We further provide measurements to highlight the benefits of the new algorithm in comparison to other similar methods.

Kokoelmat
  • Avoin saatavuus [38824]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen