Hyppää sisältöön
    • FI
    • ENG
  • FI
  • /
  • EN
OuluREPO – Oulun yliopiston julkaisuarkisto / University of Oulu repository
Näytä viite 
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Assessment of pork freshness based on changes in constituting chromophores using visible to near-infrared spectroscopy

Peyvasteh, M.; Popov, A.; Bykov, A.; Meglinski, I. (2019-12-30)

 
Avaa tiedosto
nbnfi-fe2020111189943.pdf (176.6Kt)
nbnfi-fe2020111189943_meta.xml (37.93Kt)
nbnfi-fe2020111189943_solr.xml (33.37Kt)
Lataukset: 

URL:
https://doi.org/10.1117/12.2539969

Peyvasteh, M.
Popov, A.
Bykov, A.
Meglinski, I.
SPIE
30.12.2019

M. Peyvasteh, A. Popov, A. Bykov, and I. Meglinski "Assessment of pork freshness based on changes in constituting chromophores using visible to near-infrared spectroscopy", Proc. SPIE 11202, Biophotonics Australasia 2019, 112020X (30 December 2019); https://doi.org/10.1117/12.2539969

https://rightsstatements.org/vocab/InC/1.0/
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1117/12.2539969
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2020111189943
Tiivistelmä

Abstract

Visible to near-infrared spectroscopy has been applied for non-invasive assessment of meat freshness. The measurements were done at room temperature with non-frozen pork samples. The absorbance spectra of the main chromophores in meat including oxymyoglobin, water, fat, and protein were different enough to be identified spectrophotometrically. The decreasing trend in absorbance spectra of these components over time can be associated with freshness decay. We used two configurations, fiber-optic probes and integrating sphere, to study their efficiency in meat quality evaluation. In the integrated sphere configuration, the samples experienced an immediate smooth decrease of oxymyoglobin absorbance arising from loss of superficial freshness, while degradation kinetics of water, fat and protein absorbance were detected after about 2.5 hours. In the fiber-optic configuration capable for sensing up to 570-μm depth, the drop in oxymyoglobin absorbance started after 4.5 hours which would affect directly the color of sample associated with freshness.

Kokoelmat
  • Avoin saatavuus [38618]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja