The effects of substrate layer thickness on piezoelectric vibration energy harvesting with a bimorph type cantilever

Palosaari, Jaakko; Leinonen, Mikko; Juuti, Jari; Jantunen, Heli (2018-01-05)

 
Avaa tiedosto
nbnfi-fe2018051424033.pdf (942.2Kt)
nbnfi-fe2018051424033_meta.xml (35.62Kt)
nbnfi-fe2018051424033_solr.xml (27.47Kt)
Lataukset: 

URL:
https://doi.org/10.1016/j.ymssp.2017.12.029

Palosaari, Jaakko
Leinonen, Mikko
Juuti, Jari
Jantunen, Heli
Elsevier
05.01.2018

Jaakko Palosaari, Mikko Leinonen, Jari Juuti, Heli Jantunen, The effects of substrate layer thickness on piezoelectric vibration energy harvesting with a bimorph type cantilever, Mechanical Systems and Signal Processing, Volume 106, 2018, Pages 114-118, ISSN 0888-3270, https://doi.org/10.1016/j.ymssp.2017.12.029

https://rightsstatements.org/vocab/InC/1.0/
© 2017 Elsevier Ltd. All rights reserved.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1016/j.ymssp.2017.12.029
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2018051424033
Tiivistelmä

Abstract

In this research four piezoelectric bimorph type cantilevers for energy harvesting were manufactured, measured and analyzed to study the effects of substrate layer thickness on energy harvesting efficiency and durability under different accelerations. The cantilevers had the same dimensions of the piezoelectric ceramic components, but had different thicknesses of the steel substrate (no steel, 30 µm, 50 µm and 75 µm). The cantilevers were tuned to the same resonance frequency with different sizes of tip mass (2.13 g, 3.84 g, 4.17 g and 5.08 g). The energy harvester voltage outputs were then measured across an electrical load near to the resonance frequency (∼40 Hz) with sinusoidal vibrations under different accelerations. The stress exhibited by the four cantilevers was compared and analyzed and their durability was tested with accelerations up to 2.5 g-forces.

Kokoelmat
  • Avoin saatavuus [38841]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen