Analysis of skin blood microflow oscillations in patients with rheumatic diseases

Mizeva, Irina; Makovik, Irina; Dunaev, Andrey; Krupatkin, Alexander; Meglinski, Igor (2017-07-13)

 
Avaa tiedosto
nbnfi-fe2019082325277.pdf (588.8Kt)
nbnfi-fe2019082325277_meta.xml (33.82Kt)
nbnfi-fe2019082325277_solr.xml (34.96Kt)
Lataukset: 

URL:
https://doi.org/10.1117/1.JBO.22.7.070501

Mizeva, Irina
Makovik, Irina
Dunaev, Andrey
Krupatkin, Alexander
Meglinski, Igor
SPIE
13.07.2017

Irina Mizeva, Irina Makovik, Andrey Dunaev, Alexander Krupatkin, Igor Meglinski, "Analysis of skin blood microflow oscillations in patients with rheumatic diseases," Journal of Biomedical Optics 22(7), 070501 (13 July 2017). http://dx.doi.org/10.1117/1.JBO.22.7.070501

https://rightsstatements.org/vocab/InC/1.0/
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in t his paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. http://dx.doi.org/10.1117/1.JBO.22.7.070501
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1117/1.JBO.22.7.070501
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2019082325277
Tiivistelmä

Abstract

Laser Doppler flowmetry (LDF) has been applied for the assessment of variation in blood microflows in patients with rheumatic diseases and healthy volunteers. Oscillations of peripheral blood microcirculation observed by LDF have been analyzed utilizing a wavelet transform. A higher amplitude of blood microflow oscillations has been observed in a high frequency band (over 0.1 Hz) in patients with rheumatic diseases. Oscillations in the high frequency band decreased in healthy volunteers in response to the cold pressor test, whereas lower frequency pulsations prevailed in patients with rheumatic diseases. A higher perfusion rate at normal conditions was observed in patients, and a weaker response to cold stimulation was observed in healthy volunteers. Analysis of blood microflow oscillations has a high potential for evaluation of mechanisms of blood flow regulation and diagnosis of vascular abnormalities associated with rheumatic diseases.

Kokoelmat
  • Avoin saatavuus [38865]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen