Validation of printed, skin-mounted multilead electrode for ECG measurements

Vuorinen, Tiina; Noponen, Kai; Vehkaoja, Antti; Onnia, Timo; Laakso, Eeva; Leppänen, Susanna; Mansikkamäki, Kirsi; Seppänen, Tapio; Mäntysalo, Matti (2019-06-17)

 
Avaa tiedosto
nbnfi-fe2019121848674.pdf (2.021Mt)
nbnfi-fe2019121848674_meta.xml (46.11Kt)
nbnfi-fe2019121848674_solr.xml (39.91Kt)
Lataukset: 

URL:
https://doi.org/10.1002/admt.201900246

Vuorinen, Tiina
Noponen, Kai
Vehkaoja, Antti
Onnia, Timo
Laakso, Eeva
Leppänen, Susanna
Mansikkamäki, Kirsi
Seppänen, Tapio
Mäntysalo, Matti
John Wiley & Sons
17.06.2019

Vuorinen, T., Noponen, K., Vehkaoja, A., Onnia, T., Laakso, E., Leppänen, S., Mansikkamäki, K., Seppänen, T., Mäntysalo, M., Validation of Printed, Skin‐Mounted Multilead Electrode for ECG Measurements. Adv. Mater. Technol. 2019, 4, 1900246. https://doi.org/10.1002/admt.201900246

https://rightsstatements.org/vocab/InC/1.0/
© 2019 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim. This is the peer reviewed version of the following article: Vuorinen, T., Noponen, K., Vehkaoja, A., Onnia, T., Laakso, E., Leppänen, S., Mansikkamäki, K., Seppänen, T., Mäntysalo, M., Validation of Printed, Skin‐Mounted Multilead Electrode for ECG Measurements. Adv. Mater. Technol. 2019, 4, 1900246. https://doi.org/10.1002/admt.201900246, which has been published in final form at https://doi.org/10.1002/admt.201900246. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1002/admt.201900246
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2019121848674
Tiivistelmä

Abstract

An electrocardiography (ECG) monitoring can be used to detect heart‐related abnormalities by recording cardiac activity over a period of time. The conventional 12‐lead ECG measurement system is the standard practice for the evaluation of the heart’s electrical activity. However, a recent trend is to develop patch‐type measurement devices for unobtrusive ECG monitoring by reducing device size and number of electrodes on the skin. This development aims to minimize the discomfort for the user from the wearable recording devices. A printed, bandage‐type hybrid system for continuous ECG monitoring to allow as much comfort as possible while maintaining the signal quality required for medical evaluation is proposed. Movement artifacts in recorded ECG signals are a challenge in long‐term monitoring while the patients are engaged in their everyday activities. The movement artifacts from the printed skin‐conformable electrode are compared to commercial exercise stress‐test ECG electrodes during different physical activities and stationary periods. The results show that the signal quality obtained with the multilead patch ECG electrode, manufactured with printing technologies, is comparable to electrodes currently used in healthcare.

Kokoelmat
  • Avoin saatavuus [38865]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen