Hyppää sisältöön
    • FI
    • ENG
  • FI
  • /
  • EN
OuluREPO – Oulun yliopiston julkaisuarkisto / University of Oulu repository
Näytä viite 
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Continuous stress detection using the sensors of commercial smartwatch

Siirtola, Pekka (2019-09-13)

 
Avaa tiedosto
nbnfi-fe2019121648252.pdf (339.0Kt)
nbnfi-fe2019121648252_meta.xml (23.56Kt)
nbnfi-fe2019121648252_solr.xml (29.61Kt)
Lataukset: 

URL:
https://doi.org/10.1145/3341162.3344831

Siirtola, Pekka
Association for Computing Machinery
13.09.2019

Siirtola, P. (2019). Continuous stress detection using the sensors of commercial smartwatch. Proceedings of the 2019 ACM International Joint Conference on Pervasive and Ubiquitous Computing and Proceedings of the 2019 ACM International Symposium on Wearable Computers - UbiComp/ISWC ’19. Presented at the the 2019 ACM International Joint Conference on Pervasive and Ubiquitous Computing and the 2019 ACM International Symposium. https://doi.org/10.1145/3341162.3344831

https://rightsstatements.org/vocab/InC/1.0/
© 2019 Association for Computing Machinery. This is the author's version of the work. It is posted here for your personal use. Not for redistribution. The definitive Version of Record was published in UbiComp/ISWC '19 Adjunct - Adjunct Proceedings of the 2019 ACM International Joint Conference on Pervasive and Ubiquitous Computing and Proceedings of the 2019 ACM International Symposium on Wearable Computers, https://doi.org/10.1145/3341162.3344831.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1145/3341162.3344831
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2019121648252
Tiivistelmä

Abstract

Stress detection is becoming a popular field in machine learning and this study focuses on recognizing stress using the sensors of commercially available smartwatches. In most of the previous studies, stress detection is based on partly or fully on electrodermal activity sensor (EDA). However, if the final aim of the study is to build a smartwatch application, using EDA signal is problematic as the smartwatches currently in the market do not include sensor to measure EDA signal. Therefore, this study surveys what sensors the smartwatches currently in the market include, and which of them 3rd party developers have access to. Moreover, it is studied how accurately stress can be detected user-independently using different sensor combinations. In addition, it is studied how detection rates vary between study subjects and what kind of effect window size has to the recognition rates. All of the experiments are based on publicly available WESAD dataset. The results show that, indeed, EDA signal is not necessary when detecting stress user-independently, and therefore, commercial smartwatches can be used for recognizing stress when the used window length is big enough. However, it is also noted that recognition rate varies a lot between the study subjects.

Kokoelmat
  • Avoin saatavuus [38618]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen