Over-the-air phase measurement and calibration method for 5G mmW phased array radio transceiver

Jokinen, Markku; Kursu, Olli; Tervo, Nuutti; Saloranta, Jani; Leinonen, Marko E.; Pärssinen, Aarno (2019-06-20)

 
Avaa tiedosto
nbnfi-fe2019081324081.pdf (375.2Kt)
nbnfi-fe2019081324081_meta.xml (39.82Kt)
nbnfi-fe2019081324081_solr.xml (28.94Kt)
Lataukset: 

URL:
https://doi.org/10.1109/ARFTG.2019.8739190

Jokinen, Markku
Kursu, Olli
Tervo, Nuutti
Saloranta, Jani
Leinonen, Marko E.
Pärssinen, Aarno
Institute of Electrical and Electronics Engineers
20.06.2019

M. Jokinen, O. Kursu, N. Tervo, J. Saloranta, M. E. Leinonen and A. Pärssinen, "Over-the-Air Phase Measurement and Calibration Method for 5G mmW Phased Array Radio Transceiver," 2019 93rd ARFTG Microwave Measurement Conference (ARFTG), Boston, MA, USA, 2019, pp. 1-4. doi: 10.1109/ARFTG.2019.8739190

https://rightsstatements.org/vocab/InC/1.0/
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1109/ARFTG.2019.8739190
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2019081324081
Tiivistelmä

Abstract

In this paper, over-the-air (OTA) phase measurement and calibration method for a fifth generation (5G) millimeter wave radio frequency unit is presented. The phase error measurements are done for both receiver and transmitter. The measurement results are used to calibrate the individual antenna ports of the antenna array system so that accurate radiation patterns can be formed. In order to confirm the calibration, the radiation patterns are measured with a 100 MHz wide 28 GHz 5G New Radio communication signal. The measurements show that the calibration improves the maximum power level flatness of radiation patterns and reduces side lobe levels.

Kokoelmat
  • Avoin saatavuus [38840]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen