Hyppää sisältöön
    • FI
    • ENG
  • FI
  • /
  • EN
OuluREPO – Oulun yliopiston julkaisuarkisto / University of Oulu repository
Näytä viite 
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Accurate noise floor calibration based on modified expectation maximisation of Gaussian mixture

López-Benítez, Miguel; Lehtomäki, Janne; Umebayashi, Kenta; Patel, Dhaval (2019-10-31)

 
Avaa tiedosto
nbnfi-fe2019121949044.pdf (195.3Kt)
nbnfi-fe2019121949044_meta.xml (31.15Kt)
nbnfi-fe2019121949044_solr.xml (36.32Kt)
Lataukset: 

URL:
https://doi.org/10.1109/WCNC.2019.8885661

López-Benítez, Miguel
Lehtomäki, Janne
Umebayashi, Kenta
Patel, Dhaval
Institute of Electrical and Electronics Engineers
31.10.2019

M. López-Benítez, J. Lehtomäki, K. Umebayashi and D. Patel, "Accurate Noise Floor Calibration based on Modified Expectation Maximisation of Gaussian Mixture," 2019 IEEE Wireless Communications and Networking Conference (WCNC), Marrakesh, Morocco, 2019, pp. 1-6. doi: 10.1109/WCNC.2019.8885661

https://rightsstatements.org/vocab/InC/1.0/
© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1109/WCNC.2019.8885661
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2019121949044
Tiivistelmä

Abstract

An accurate estimation of the noise floor is of paramount importance for an optimum performance of spectrum sensing in Cognitive Radio (CR). The most common approach followed by existing noise floor estimation methods is to attempt to isolate a set of noise-only samples based on a given energy/power threshold. However, this approach is unreliable and in general unable to provide accurate estimations of the noise floor, in particular under low SNR conditions where the power of the Primary User (PU) signal is comparable to the noise floor of the CR device. In this context, this work considers a different approach where the power observed by the CR device is modelled as a Gaussian mixture. Based on a mathematical analysis of the relation among the parameters of the obtained Gaussian mixture, a modified version of the well-known Expectation Maximisation (EM) algorithm is proposed to fit the Gaussian mixture to the observed power values and provide an estimation of the noise floor, something that the general EM algorithm fails to achieve in this scenario. The obtained results demonstrate that the proposed method provides a highly accurate estimation of the noise floor in the presence of PU signals over the whole range of SNR values.

Kokoelmat
  • Avoin saatavuus [37688]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen