Effect of solvent lamination on roll-to-roll hot-embossed PMMA microchannels evaluated by optical coherence tomography

Lauri, Janne; Liedert, Christina; Kokkonen, Annukka; Fabritius, Tapio (2019-04-24)

 
Avaa tiedosto
nbnfi-fe2019081424168.pdf (895.0Kt)
nbnfi-fe2019081424168_meta.xml (33.06Kt)
nbnfi-fe2019081424168_solr.xml (34.02Kt)
Lataukset: 

URL:
https://doi.org/10.1088/2053-1591/ab11a7

Lauri, Janne
Liedert, Christina
Kokkonen, Annukka
Fabritius, Tapio
IOP Publishing
24.04.2019

Janne Lauri et al 2019 Mater. Res. Express 6 075333. https://doi.org/10.1088/2053-1591/ab11a7

https://rightsstatements.org/vocab/InC/1.0/
© 2019 IOP Publishing. This is the pre-peer reviewed version of the following article: Janne Lauri et al., Effect of solvent lamination on roll-to-roll hot-embossed PMMA microchannels evaluated by optical coherence tomography, Materials Research Express 6(7): 075333 (2019), which has been published in final form at DOI: 10.1088/2053-1591/aade7b. This article may be used for non-commercial purposes in accordance with IOP Publishing terms and conditions for use of self-archived versions.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1088/2053-1591/ab11a7
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2019081424168
Tiivistelmä

Abstract

Manufacturing of microfluidic based diagnostic devices requires small tolerances and uniform quality to guarantee reliable and repeatable test results. This work describes characterization of morphological changes that occur to a hot embossed PMMA microfluidic channel after solvent lamination with a PMMA lid. A non-contact cross-sectional analysis of the lidded microfluidic device was performed by optical coherence tomography (OCT). The solvent induced morphology change led to a porous structure in bottom corners of hot-embossed channels, which allowed a fluid to absorb in the material. The measurements of solvent diffusion showed faster diffusion rate at the corners of the channel, in which the accumulated stress during the embossing process was the highest. The stress profile was verified by simulation of von Mises stresses during a molding phase of a hot embossing process. The porous structure with increased fluid diffusion has an unwanted effect on bioassay result, e.g. when detection molecules leak into the substrate thus leading to unspecific signal on chip. OCT was found to be a valuable, non-destructive imaging method to monitor solvent diffusion process and lamination process quality.

Kokoelmat
  • Avoin saatavuus [38840]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen