Hyppää sisältöön
    • FI
    • ENG
  • FI
  • /
  • EN
OuluREPO – Oulun yliopiston julkaisuarkisto / University of Oulu repository
Näytä viite 
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Impact of blood volume on the diffuse reflectance spectra of human skin in visible and NIR spectral ranges

Zherebtsov, Evgeny; Doronin, Alexander; Bykov, Alexander; Popov, Alexey; Meglinski, Igor (2017-03-30)

 
Avaa tiedosto
nbnfi-fe2019042513195.pdf (387.5Kt)
nbnfi-fe2019042513195_meta.xml (34.64Kt)
nbnfi-fe2019042513195_solr.xml (32.76Kt)
Lataukset: 

URL:
https://doi.org/10.1117/12.2250855

Zherebtsov, Evgeny
Doronin, Alexander
Bykov, Alexander
Popov, Alexey
Meglinski, Igor
SPIE
30.03.2017

Evgeny Zherebtsov, Alexander Bykov, Alexey Popov, Alexander Doronin, and Igor Meglinski "Impact of blood volume changes within the human skin on the diffuse reflectance measurements in visible and NIR spectral ranges", Proc. SPIE 10063, Dynamics and Fluctuations in Biomedical Photonics XIV, 1006312 (30 March 2017); doi: 10.1117/12.2250855; https://doi.org/10.1117/12.2250855

https://rightsstatements.org/vocab/InC/1.0/
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this publication for a fee or for commercial purposes, and modification of the contents of the publication are prohibited.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1117/12.2250855
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2019042513195
Tiivistelmä

Abstract

We consider changes in the volume of blood and oxygen saturation caused by a pulse wave and their influence on the diffuse reflectance spectra in the visible/NIR spectral range. CUDA-based Monte-Carlo model was used for routine simulation of detector depth sensitivity (sampling volume) and skin spectra, and their variations associated with physiological changes in the human skin. The results presented in the form of animated graphs of sampling volume changes for scaling of the parameters of the main human skin layers related to the results of experimental measurements are of particular interest for pulse oximetry, photoplethysmography, Doppler flowmetry, reflectance spectroscopy.

Kokoelmat
  • Avoin saatavuus [37559]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen