Hyppää sisältöön
    • FI
    • ENG
  • FI
  • /
  • EN
OuluREPO – Oulun yliopiston julkaisuarkisto / University of Oulu repository
Näytä viite 
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
  •   OuluREPO etusivu
  • Oulun yliopisto
  • Avoin saatavuus
  • Näytä viite
JavaScript is disabled for your browser. Some features of this site may not work without it.

Terahertz time-domain spectroscopy for non-invasive assessment of water content in biological samples

Borovkova, Mariia; Khodzitsky, Mikhail; Demchenko, Petr; Cherkasova, Olga; Popov, Alexey; Meglinski, Igor (2018-04-20)

 
Avaa tiedosto
nbnfi-fe2018042418421.pdf (2.438Mt)
nbnfi-fe2018042418421_meta.xml (38.02Kt)
nbnfi-fe2018042418421_solr.xml (32.87Kt)
Lataukset: 

URL:
https://doi.org/10.1364/BOE.9.002266

Borovkova, Mariia
Khodzitsky, Mikhail
Demchenko, Petr
Cherkasova, Olga
Popov, Alexey
Meglinski, Igor
Optical Society of America
20.04.2018

Mariia Borovkova, Mikhail Khodzitsky, Petr Demchenko, Olga Cherkasova, Alexey Popov, and Igor Meglinski, "Terahertz time-domain spectroscopy for non-invasive assessment of water content in biological samples," Biomed. Opt. Express 9, 2266-2276 (2018)

https://rightsstatements.org/vocab/InC/1.0/
© 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement. https://www.osapublishing.org/library/license_v1.cfm#VOR-OA
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1364/BOE.9.002266
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2018042418421
Tiivistelmä

Abstract

We apply terahertz time-domain spectroscopy for the quantitative non-invasive assessment of the water content in biological samples, such as Carpinus caroliniana tree leaves and pork muscles. The developed experimental terahertz time-domain spectroscopy system operates both in transmission and reflection modes. The Landau-Looyenga-Lifshitz-based model is used for the calculation of the water concentration within the samples. The results of the water concentration measurements are compared with the results of the gravimetric measurements. The obtained results show that the water content in biological samples can be measured non-invasively, with a high accuracy, utilizing terahertz waves in transmission and reflection modes.

Kokoelmat
  • Avoin saatavuus [38386]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen