TReNDS—software for reaction monitoring with time‐resolved non‐uniform sampling

Urbańczyk, Mateusz; Shchukina, Alexandra; Gołowicz, Dariusz; Kazimierczuk, Krzysztof (2018-09-25)

 
Avaa tiedosto
nbnfi-fe2018121951302.pdf (1.334Mt)
nbnfi-fe2018121951302_meta.xml (32.06Kt)
nbnfi-fe2018121951302_solr.xml (35.06Kt)
Lataukset: 

URL:
https://doi.org/10.1002/mrc.4796

Urbańczyk, Mateusz
Shchukina, Alexandra
Gołowicz, Dariusz
Kazimierczuk, Krzysztof
John Wiley & Sons
25.09.2018

Urbańczyk M, Shchukina A, Gołowicz D, Kazimierczuk K. TReNDS—Software for reaction monitoring with time‐resolved non‐uniform sampling. Magn Reson Chem. 2019;57:4–12. https://doi.org/10.1002/mrc.4796

https://rightsstatements.org/vocab/InC/1.0/
© 2018 John Wiley & Sons, Ltd. This is the peer reviewed version of the following article: Urbańczyk M, Shchukina A, Gołowicz D, Kazimierczuk K. TReNDS—Software for reaction monitoring with time‐resolved non‐uniform sampling. Magn Reson Chem. 2019;57:4–12, which has been published in final form at https://doi.org/10.1002/mrc.4796. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.
https://rightsstatements.org/vocab/InC/1.0/
doi:https://doi.org/10.1002/mrc.4796
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2018121951302
Tiivistelmä

Abstract

NMR spectroscopy, used routinely for structure elucidation, has also become a widely applied tool for process and reaction monitoring. However, the most informative of NMR methods—correlation experiments—are often useless in this kind of applications. The traditional sampling of a multidimensional FID is usually time‐consuming, and thus, the reaction‐monitoring toolbox was practically limited to 1D experiments (with rare exceptions, e.g., single‐scan or fast‐sampling experiments). Recently, the technique of time‐resolved non‐uniform sampling (TR‐NUS) has been proposed, which allows to use standard multidimensional pulse sequences preserving the temporal resolution close to that achievable in 1D experiments. However, the method existed only as a prototype and did not allow on‐the‐fly processing during the reaction.

In this paper, we introduce TReNDS: free, user‐friendly software kit for acquisition and processing of TR‐NUS data. The program works on Bruker, Agilent, and Magritek spectrometers, allowing to carry out up to four experiments with interleaved TR‐NUS. The performance of the program is demonstrated on the example of enzymatic hydrolysis of sucrose.

Kokoelmat
  • Avoin saatavuus [38655]
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen
 

Selaa kokoelmaa

NimekkeetTekijätJulkaisuajatAsiasanatUusimmatSivukartta

Omat tiedot

Kirjaudu sisäänRekisteröidy
oulurepo@oulu.fiOulun yliopiston kirjastoOuluCRISLaturiMuuntaja
SaavutettavuusselosteTietosuojailmoitusYlläpidon kirjautuminen